Configurator · Victron · Home battery

Victron ESS configurator

How many PV panels do you have? From that the configurator works out which charge controllers, which MultiPlus and which battery fit – and compiles the parts list with Victron part numbers, cables and the settings for commissioning. At Victron the information is spread out: one compatibility page per battery manufacturer, plus the ESS manual, inverter manuals and datasheets.

1 · Your system

From the number of panels and your consumption the configurator proposes charge controllers, MultiPlus and battery and enters them in the fields below. You can change every part there.

On the Victron the configurator splits the panels across charge controllers.

On your annual bill; it helps determine the size of the storage.

Panel voltage rises in the cold; this decides how many panels may go in series.

With limiting, fewer controllers are often enough; at the midday peak they then do not take the full panel power.

2 · Inverter/charger and GX device

One unit on a three-phase connection balances the sum of all phases via a three-phase meter.

Built in is only available on the 3 and 5 kVA models and only for a single unit.

3 · Battery

Leave empty and the parts list gives the minimum.

Pre-filled from the battery data; the charge controllers only start above it.

4 · Metering and loads

The usual case: the house wiring stays, the MultiPlus works in parallel.

Your parts list

Links marked with an asterisk in the parts list are affiliate links. As an Amazon Associate I earn from qualifying purchases; the price is unchanged for you. What goes into the list does not depend on it: there is only a link where the offer is exactly the named part – as a checked product or as an Amazon search whose first result matches. The Victron offers checked are sold by specialist dealers, not Victron itself.

Produces
proposal from number of panels and consumption, parts list and settings for a grid-parallel ESS with a 48 V MultiPlus-II
Batteries
24 manufacturers from AXIstorage to ZYC Energy
Panels
six series from AIKO to Trina, others with values entered by hand
Basis
Victron compatibility pages and the manufacturer documents linked there, ESS manual, MultiPlus-II manual and datasheet, panel datasheets, HTW Berlin's rules of thumb
Your data
stays in your browser, nothing is stored
As of
15 October 2026 · primary sources below, check date for each
Author
Julian Haag, state-certified electrical engineering technician

At home I run a Pylontech US2000C on a Victron system. Finding the right parts was hard – not because the information is missing, but because it sits in many places. The most important piece depends on the battery: Victron makes the cable to the GX device in two pin-outs, and with Pylontech the right one differs even within the same series.

How the proposal is made

The proposal answers four questions in turn. Each answer rests on a source listed below.

What the proposal does not know: prices, availability, your roof areas and how many battery modules may work together at most. Parallel strings on one controller have the same length; that all panels in a string should face the same way is something the configurator cannot check.

Panels in the selection, values at 25 °C according to the manufacturer datasheet, checked on 15 Oct 2026
SeriesPowerVocIscTemperature coefficient VocDatasheet
AIKO Neostar 2P MAH54Mw450–485 W40.94–41.36 V14.12–14.41 A−0.22 %/KV4.1_202510
JA Solar JAM54D40/MB420–445 W38.28–39.65 V13.65–13.90 A−0.25 %/KGlobal-EN-20240729A
JA Solar JAM72D40/MB580–605 W51.95–53.00 V13.84–14.09 A−0.25 %/KGlobal-EN-20241105A
Jinko Tiger Neo 3.0 48QL6-DB460–485 W35.69–36.94 V15.70–15.94 A−0.24 %/KJKM460-485N-48QL6-DB-F4-EU
LONGi Hi-MO X10 LR7-54HVH480–505 W40.29–40.85 V15.13–15.62 A−0.20 %/KBGV03 20260509
Trina Vertex S+ NEG9R.28450–475 W52.9–55.0 V10.74–10.93 A−0.24 %/KTSM_EN_2026_A

The selection covers widely used series from large manufacturers whose datasheet the manufacturer itself offers for download. If your panel is missing, choose “other panel” and enter the values from its datasheet.

How the list is built

Every line comes from a Victron source or from a manufacturer document that Victron links on its compatibility page; which one is listed below. Three things decide whether the system starts up, and all three depend on the battery:

BMS cable, minimum GX firmware and DVCC per battery, according to Victron, checked on 14 Oct 2026; information from manufacturer documents on the Victron pages in brackets, checked on 15 Oct 2026
BatteryBMS cableGX at leastDVCC
AXIstorage Li 7S / 9SType Bpage outdated (states v1.72)not stated by Victron
Bluenova, SSS rangestandard network cablev2.12switches on by itself
BMZ ESS 7.0, 9.0, X, ZType Bpage outdated (states v1.72)SVS, STS off (table on the Victron page)
BSLBATTType Bv2.52on, SVS on (BSLBATT guide)
BYD Battery-Box Premium LVS, LVL, LV Flex 5.0Type Av2.52on; SVS, STS off
BYD Battery-Box LV5.0+Type Av3.20on; SVS, STS off
Cegasa eBick LV, LV 15standard network cable, not type A or Bv2.90automatic on the BMS-Can port
Discover HELIOS ESSType Av2.40by hand: on; SVS, STS off; SCS on
Dyness (DL5.0C, Powerbox, PowerBrick and others)Type A, explicitly not type Bv3.31by hand: on; SVS, STS, SCS off
Exide Sonnenschein Module Prosupplied with the batteryv2.90by hand: on; SVS, STS off
Freedom Won LiTEstandard network cablev2.60 recommendedforced on, SVS on
Freedom Won eTowersupplied (type B according to Victron)v2.60 recommendedforced on, SVS on
Hubble with CloudLinkType Av3.00forced on
LBSAType Av3.40by hand: on; SVS, STS off
Leoch LR51.2-100Type Bv3.50on; SVS, STS off
MeterBoostType A or Bv3.40enforced: on, SVS on (MeterBoost guide)
Pylontech US2000C/D, US3000C, US5000(B), UP5000, Force-LType Av3.50automatic on the BMS-Can port
Pylontech US2000, US3000 (older design)Type Bv3.50automatic on the BMS-Can port
Pytes V5°, E-BOX, Pi LV1Type Av3.31on; SVS, STS off
SolarMD SS4037, SS4074, SS202UTP cable to the Logger V2v2.15by hand: on; SVS, STS off
SolunaType A or Bv3.60automatic: on, SVS on
StorageDOCK ESType Bv3.70automatic: on, SVS on, SCS off
SunwodaType Av3.60automatic: on; SVS, STS off
TAB e.module L5.1Type A or Btested with v3.63not stated by Victron
VoltsmileType Av3.80automatic: on, SVS off
WeConot stated by Victronv3.31enforced: on, SVS on, STS off
ZYC Energy SIMPO 5000Type A (ZYC guide)not stated by Victronnot stated by Victron

Victron now lists new part numbers for both cables: type A ASS030710118, type B ASS030720118, each 1.8 m; the 5 m versions end in …150. The battery pages still give the old numbers ending in …018; the product page points to the new ones.

The GX device decides how many CAN connections stay free. Cerbo GX MK2, Cerbo GX MK3 and Ekrano GX have two: one for the battery, one for VE.Can devices. The Cerbo-S GX has only one, and the built-in GX of the MultiPlus-II GX has a dedicated BMS-Can port on which VE.Can devices do not work. An MPPT solar charger then connects via VE.Direct.

How the MPPT sizing works

For panels on the Victron the configurator uses the values from the panel datasheet; they apply at 25 °C cell temperature (standard test conditions). Every controller with its parallel strings has to meet the limits in Victron's datasheets:

SmartSolar controllers in the selection, values according to the Victron datasheet, checked on 14 Oct 2026
ControllerNominal power at 48 VMax. short-circuit currentMax. open-circuit voltage (start/operation)
SmartSolar MPPT 150/352,000 W40 A150 V (145 V)
SmartSolar MPPT 150/452,600 W50 A150 V (145 V)
SmartSolar MPPT 150/60-Tr3,440 W50 A150 V (145 V)
SmartSolar MPPT 150/70-Tr4,000 W50 A150 V (145 V)
SmartSolar MPPT 250/60-Tr3,440 W35 A250 V (245 V)
SmartSolar MPPT 250/70-Tr4,000 W35 A250 V (245 V)

In the heat the panel voltage drops below the 25 °C value. By how much is given as the temperature coefficient in the panel datasheet; the configurator does not calculate this case. It therefore prefers long strings – allow a margin between MPP voltage and battery voltage.

More controllers than the GX device has VE.Direct ports connect to a USB port via the VE.Direct to USB interface (ASS030530010). According to the GX manual, the Cerbo GX MK2 handles up to 15 VE.Direct devices, the MK3 up to 25.

Registration and connection

A MultiPlus-II in ESS mode works in parallel with the grid. For registration with the German grid operator, Victron provides the unit certificate and the certificate for the grid and system protection (NA-Schutz) to VDE-AR-N 4105:2018-11 – for the 3, 4.5, 5 and 6.5 kVA models (also as GX) and for 8, 10 and 15 kVA, there additionally in three-phase configuration. They are on the product pages under Downloads.

Registration needs a single-line diagram. What it has to show is covered in the article PV single-line diagram, which also has sample sheets with storage. If you would rather not draw it yourself: I draw it for €50. Within one month of commissioning, the battery goes into the Marktstammdatenregister.

Connecting to 230/400 V is reserved for a qualified electrician. The parts list does not replace planning the AC side: circuit protection, residual current protection and the meter panel are decided there.

What the configurator does not cover

Frequently asked questions

How large should the battery be for my PV system?

According to HTW Berlin's rules of thumb, at most 1.5 kWh of usable capacity per kW of PV power and at most 1.5 kWh per 1,000 kWh of annual consumption; the smaller value applies. With 10 kW of PV power and 4,000 kWh of consumption that is 6 kWh. A larger battery raises self-sufficiency only slightly, and below 0.5 kW of PV power per 1,000 kWh of consumption there is too little surplus for a battery, according to HTW. With Victron there is one more point: the battery has to carry the MultiPlus, and some manufacturers require more modules for that than the rule of thumb gives.

Which cable connects the battery to the Victron GX device?

Usually Victron's VE.Can to CAN-bus BMS cable, in type A or type B; which one depends on the battery model, with Pylontech even on the design within the same series. Cegasa, Bluenova and Freedom Won LiTE use a standard network cable instead; Exide and the Freedom Won eTower come with their own cable. The table further up lists the mapping for all 24 manufacturers. The cable Pylontech supplies does not fit the connection to the GX device.

Do I need a grid meter?

Yes, as soon as loads or a PV inverter sit between the grid connection and the Victron – the usual case, where the house wiring stays as it is. Without a meter, the GX device then works with wrong grid and consumption figures. Only if everything is on the MultiPlus AC output can you do without. Single-phase, that is the ET112; on a three-phase connection Victron recommends the EM24 rather than the ET340, because it counts the net sum.

Are my entries stored?

No. Proposal and parts list are built in your browser. Number of panels, consumption, your selection and panel data only appear in the part of the address after the #, which the browser does not send to the server; Google Analytics receives the address without that part. All that is recorded is that a parts list was created or copied, plus battery manufacturer, layout and type of GX device.

Sources

The information comes from Victron Energy's documentation, from the manufacturer documents Victron links on its compatibility pages, from the panel manufacturers' datasheets and from HTW Berlin. If in doubt, the current version at the manufacturer and the battery manual take precedence.

Planning a Victron system and want to control it with Home Assistant afterwards? Write to me – the first conversation is free.