Running a heat pump on electricity prices
Relay contact, Modbus or the manufacturer's cloud – which route holds up, what funding has required since July 2026, and where control runs into its limits.
Read the article →Technical article · Manufacturers
For its subsidy-eligible heat pumps Vaillant names three routes to controllability under section 14a and explicitly recommends one of them: EEBUS. Vaillant describes the prerequisites precisely; a unit list with software versions, as Bosch and Buderus publish, is not on the manufacturer pages. And there is one point where Vaillant renders the ruling inaccurately.
From this article on Amazon (Germany):
Vaillant VR 940f*
Marked *: affiliate links. As an Amazon Associate I earn from qualifying purchases.
Vaillant writes: “For the required controllability under section 14a EnWG, Vaillant's subsidy-eligible heat pumps offer the following options: utility contact, EEBUS, energy management system”.
On the utility contact, Vaillant writes: “However, switching off is only permitted for a maximum of two hours a day and only in an emergency.” The Bundesnetzagentur's ruling does contain a two-hour limit – but for preventive control, which the grid operator may use as a transitional measure until 31 December 2028 at the latest: its use “is limited to two hours a day” (clause 10.5). For grid-oriented control the ruling sets no hourly limit. A device that only knows on and off goes to the next lower technically possible value there (clause 4.6) – in other words, off.
According to Vaillant, “all current Vaillant heat pumps come with the myVAILLANT connect internet module as standard”, and many existing units already have one. For EEBUS, Vaillant names three components:
EEBUS is activated in the myVAILLANT app: open the network settings, select and activate “EEBUS”, start the connection on the other side in parallel, select the device there and connect after the trust has been established. For energy management functions, “energy management” must also be activated in the main menu. According to Vaillant, there are no additional costs if an internet module is present.
What the two manufacturer pages do not contain: which heat pump implements a control box's instruction via EEBUS from which software version, and how it behaves if the connection drops. Bosch, Buderus and Daikin publish that. With Vaillant, put the question to the manufacturer before buying – in writing, with the model designation.
For section 14a, any route the manufacturer names is enough. For subsidising a newly installed heat pump it is not: under number 3.4.3, the BEG EM directive of 17 August 2026 requires a “digital interface for grid-oriented control” that is “interoperable” and enables control under section 14a “including the status and feedback information required for it”. A contact that opens or closes provides no feedback. From 1 July 2027, the interface of newly installed heat pumps must also follow a format in line with the Code of Conduct for Energy Smart Appliances, “for example EEBUS in accordance with VDE-AR-E 2829-6”.
Whether a specific installation is subsidised is decided by the funding body, not the manufacturer. The connection routes compared: Running a heat pump on electricity prices.
Vaillant names three routes: the utility contact, which switches off the heat pump or only the auxiliary heater, the EEBUS interface, through which power consumption can be dimmed, and an energy management system that distributes the available power across several devices. Vaillant recommends EEBUS.
According to Vaillant, a compatible VRC 700(f) or VRC 720(f) controller, a VR 920, VR 921 or VR 940(f) internet module commissioned via the myVAILLANT app, and an established connection to the other side. EEBUS is activated in the app under the network settings.
The two-hour limit Vaillant mentions for the utility contact is in the Bundesnetzagentur's ruling for preventive control, which grid operators may use as a transitional measure until the end of 2028 at the latest. For grid-oriented control, the ruling sets no hourly limit.
The manufacturer information comes exclusively from the manufacturer's own documents, each with its date and the date it was checked. Manufacturer documents change with every firmware release; what counts is the version valid at the time of installation. Quotations from German documents are our translation.
This article reproduces manufacturer information; it replaces neither Vaillant's documentation nor the technical connection conditions of your grid operator. Connection and registration are reserved for a registered electrical contractor. Haag Automation has no business relationship with Vaillant.