The idea is tempting: midday surplus is worth almost nothing, an immersion heater costs little, and the cylinder is in the basement anyway. The calculation still rarely works out – for a reason that has nothing to do with the price of electricity.
From this article on Amazon (Germany):
power controller for immersion heaters* ·
immersion heater for the cylinder* ·
clamp-on temperature sensor*
Marked *: affiliate links. As an Amazon Associate I earn from qualifying purchases.
The appeal is obvious: the PV array runs at midday, the surplus goes to the grid for a few cents, and there is a cylinder in the basement that could absorb heat. Three routes lead there, and what separates them is how much heat you get out of a kilowatt-hour of electricity.
Search on Amazon.de: power controller for immersion heaters* · immersion heater for the cylinder* · clamp-on temperature sensor*
An electric immersion heater turns one kilowatt-hour of electricity into one kilowatt-hour of heat. Physics allows no more and no less – its efficiency is one. A heat pump takes most of the heat from its surroundings and needs only a fraction of that electricity.
How small that fraction must be at minimum is set by the German funding rules: subsidised heat pumps have to be designed to reach a seasonal performance factor of at least 3.0. A unit at that floor therefore needs one third of the electricity for the same amount of heat.
This is why the calculation goes against the immersion heater even when the surplus is free: the same kilowatt-hour, put into the heat pump, produces several times the heat. The heater only wins where the heat pump cannot reach – and where the surplus would genuinely go unused otherwise.
Which is exactly the condition that has to be tested: does the surplus actually go unused? Anyone with a battery, a car to charge, or a heat pump already making hot water is competing with themselves. The immersion heater is then not the use of a surplus but the displacement of a better use.
Four cases where the decision goes the other way:
The rule is simple; its parameters are not. Do not switch on „surplus present“ but on a threshold with a gap – on when the surplus is sufficient for a minimum duration, off well below that. Without the gap the control cycles every minute as soon as a cloud passes.
More important than the threshold is the priority order: who gets the surplus first? The usual and sensible order is house load, then battery, then car, then heat. Hot water sits far back because it monetises the energy worst – unless the battery is full anyway and the car is not there.
How that order interacts with the wallbox is covered in the article on PV surplus charging; this one stays on the heat side.
Immersion heaters run on 230 or 400 volts and draw currents where cable cross-section and protection have to be right. Fitting a power controller, protecting the circuit and connecting the heater are jobs for a qualified electrician. And one point that is often missed: a controller that modulates by phase-angle control produces mains disturbance – which design is admissible in a given network is not decided by the datasheet alone. How much voltage that current drops along the supply line is shown by the voltage drop calculator on xmoo.app (in German).
Safety functions stay where they are: the cylinder's safety temperature limiter is not a comfort feature for an automation to override. Control that bypasses it is no longer energy management.
Hot water is only part of the question of how a heat pump is driven at all. The connection routes, the digital interface required since July 2026 and the pitfalls of the control loop are covered in the main article, running a heat pump on electricity prices.
The efficiency comparison rests on the minimum requirement in the German funding rules; the efficiency of an electric immersion heater follows directly from conservation of energy and needs no source.