Metering · Distribution board
Energy metering in the distribution board
Direct or CT metering, how much space the board needs and why checking against the meter matters.
Read the article →Article · Metering · Battery
A plug-in battery that only supplies as much as the house needs at that moment has to know what is happening at the grid connection. Every manufacturer sells its own meter for this. Almost all of them also accept a Shelly, though, and some accept a reading head on the electricity meter. Three questions decide the purchase: What does my battery accept? Who installs the meter? And do the readings reach Home Assistant as well, without a detour through a cloud?
From this article on Amazon (Germany):
everHome EcoTracker IR* ·
Anker SOLIX Smart Meter Gen 2* ·
Marstek CT002*
Marked *: affiliate links. As an Amazon Associate I earn from qualifying purchases.
What the shop calls a “smart meter” is three different kinds of device.
Installing in the distribution board needs an electrician. All four manufacturers say so: Anker recommends a qualified electrical contractor for the Smart Meter Gen 2, Marstek writes for the CT002 “installation must be performed by a professional electrician”, the EcoFlow STREAM Ultra manual says “Have a qualified electrician install the smart meter”, and Zendure advises hiring an electrician for the Shelly. How much space the board needs and what to consider for the upstream protection is covered in the article on energy metering referred to below.
The manufacturers keep their lists per battery model. The table reflects what they name on the date checked; anything not named is shown as a dash. A dash does not mean it certainly does not work, only that the manufacturer does not promise it.
| Battery | Vendor meter | Shelly | Reading head |
|---|---|---|---|
| Anker Solarbank 3 E2700 Pro | Anker Smart Meter; Gen 2 with restrictions¹ | 3EM, Pro 3EM | – |
| Anker Solarbank 4 E5000 Pro | Smart Meter, Smart Meter Gen 2 | 3EM, Pro 3EM | everHome EcoTracker IR |
| Anker Solarbank Max AC | Smart Meter (A17X7), Smart Meter Gen 2 | 3EM, Pro 3EM | EcoTracker IR announced |
| Marstek Venus E 3.0 | CT002 | Pro 3EM (“Shelly Series or Similar”) | CT003; P1 meter, EcoTracker |
| EcoFlow STREAM Ultra | EcoFlow × Shelly Smart Meter (a Pro 3EM) | Pro 3EM | – |
| Zendure SolarFlow 1600 AC+, 2400 Pro, 2400 AC+ | Smart Meter 3CT | 3EM, Pro 3EM | Smart Meter D0/P1, everHome EcoTracker IR |
¹ According to Anker, the PV/ESS CT port of the Gen 2 cannot be used with Solarbank 1, 2 and 3; automatic phase detection, circuit protection and monitoring of third-party PV systems are then not available.
Two things stand out. First, the manufacturers name models, not product families: Shelly now also sells other three-phase meters, and none of the four names those. EcoFlow even gives article numbers (SPEM-003CEBEU120 and SPEM-003CEBEU). Before buying, it is worth comparing the exact designation with the list for your own battery. Second, a system needs only one meter. The STREAM Ultra manual says so explicitly: “Only 1 smart meter is needed for a STREAM system.”
That a battery accepts a Shelly does not say how it reads it. The manufacturers describe this differently:
For the purchase this means: anyone who does not want the control to depend on an internet connection should ask not only “does the meter fit?” but also “by which route?”. Whether the Shelly Cloud route also applies to the newer Solarbanks is not stated in Anker's compatibility lists.
The Shelly itself can serve several consumers at once. Its interface knows several channels (HTTP, WebSocket, MQTT, UDP) and, according to Shelly, allows up to six simultaneous non-persistent connections. The battery and Home Assistant can therefore read the same meter side by side; a second meter just for Home Assistant is not needed.
For controlling the battery this makes no difference. But anyone who wants to fill the energy dashboard or switch other loads on surplus needs the readings in Home Assistant, ideally locally and without delay. This is where the meters differ most.
| Meter | Route | Local |
|---|---|---|
| Shelly 3EM, Pro 3EM | Shelly integration, part of Home Assistant | yes |
| Anker SOLIX Smart Meter Gen 2 | Anker's official integration (HACS), Modbus TCP, port 502 | yes |
| Anker SOLIX Smart Meter (A17X7) | community integration via the Anker cloud | no |
| everHome EcoTracker IR | the manufacturer's local REST interface | yes |
| Marstek CT002, CT003 | via the battery's Open API; meter readings in Home Assistant via a community integration | yes |
| Zendure 3CT, D0/P1 | not described by the manufacturer | – |
Shelly. The integration talks directly to the device; according to the documentation no cloud connection is needed. What the Pro 3EM delivers and how import and export are counted correctly in the energy dashboard is covered in the article Energy dashboard with the Shelly Pro 3EM. The section on netting matters there: the electricity meter sums across all three line conductors, the Shelly's energy counters per phase do not.
Anker Smart Meter Gen 2. Anker has published its own integration for Home Assistant that works locally over Modbus TCP and supports the Smart Meter Gen 2, according to Anker with all firmware versions. Modbus TCP has to be switched on in the Anker app first: select the device, settings, “Three-Party Control Settings”, the “Modbus TCP” toggle. The app also shows the IP address that Home Assistant needs. According to Anker, the readings update every five seconds.
First Anker Smart Meter (A17X7). It is not on the official integration's list. What remains is the community integration “Anker Solix”, which by its own account depends on the Anker cloud. For Solarbank 2 systems the cloud regularly updates only every five minutes, according to its documentation; that is not enough for real-time readings.
everHome EcoTracker. The manufacturer documents a local REST interface, switched on by default in the everHome app under “Local HTTP server”. Among other things it delivers the current power in watts (negative when exporting) and the meter readings for import and export in watt-hours. Because the reading head takes these readings directly from the electricity meter, they are the same registers that billing is based on. In Home Assistant the built-in REST integration is enough:
rest:
- resource: "http://192.168.1.50/v1/json"
scan_interval: 10
sensor:
- name: "Grid power"
value_template: "{{ value_json.power }}"
unit_of_measurement: "W"
device_class: power
state_class: measurement
- name: "Grid import"
value_template: "{{ value_json.energyCounterIn }}"
unit_of_measurement: "Wh"
device_class: energy
state_class: total_increasing
- name: "Grid export"
value_template: "{{ value_json.energyCounterOut }}"
unit_of_measurement: "Wh"
device_class: energy
state_class: total_increasing
The address is an example; replace it with the IP address of the EcoTracker on your own network, ideally with a fixed
assignment in the router. scan_interval is the polling interval in seconds. The two energy sensors can be
entered in the energy dashboard as grid import and grid export.
Marstek. For the CT002 and CT003 themselves, Marstek names no interface. The battery passes their readings on, though: its local Open API has a component for the meter that delivers the power per phase and the meter readings. According to Marstek it applies to the Venus C/E, A/D and E mini and is enabled in the Marstek app with a UDP port. Marstek points out that some built-in functions of the battery may be disabled in the process to avoid conflicting commands. Marstek offers its own integration for Home Assistant, for manual installation from Home Assistant 2026.9. According to its description, though, it only delivers battery, operating mode and PV inputs, no meter readings. Those are fetched by the community integration “Marstek Local API” over the same interface. Marstek's integration is not yet part of Home Assistant itself; the request for it has been under review since August 2026.
Zendure. For the 3CT and the D0/P1 meter, Zendure describes Smart CT mode, but no interface to Home Assistant.
Anyone who needs the readings directly from the meter and with official support is better served by a Shelly, the Anker Smart Meter Gen 2 or an EcoTracker, provided their battery accepts it.
The reading head is the only type that needs no work in the distribution board. Marstek explicitly writes about the CT003 that it can be installed without an electrician. But it has a precondition that often only becomes apparent after the purchase: the electricity meter must output the current power.
On a German modern metering device (“moderne Messeinrichtung”, the digital meter without a communication module), this is not the case out of the box. The user manual from the distribution system operator Netze ODR describes it precisely for its meters: in the reduced data set, the INFO interface only outputs the meter reading without decimals. The meter outputs the instantaneous power only in the extended data set, which is unlocked in the meter's menu, and the menu in turn asks for the PIN. It is operated by shining a torch on the optical sensor. The data then arrive every second.
The PIN is issued by the metering point operator. At Netze ODR it can be retrieved online with the 14-digit meter number and the market location number, at Netze BW through customer service. For other metering operators, the route is in the instructions for the meter.
Before buying a reading head: obtain the PIN, unlock the extended output on the meter and check whether a power reading in watts appears on the display. Only then is it certain that the head will get something to control with.
A recommendation by brand makes little sense, because the battery already narrows the choice. The more useful question is what is needed besides the control.
How the control itself works and why it never quite reaches zero is covered in the article Zero export with Home Assistant. What a battery actually saves in the end is calculated in the article Controlling a home battery with Home Assistant.
On Amazon (Germany): everHome EcoTracker IR* · search for Anker SOLIX Smart Meter Gen 2* · Marstek CT002*
Read on: where the meter sits in the distribution board, how much space it needs and how to check the measurement against the electricity meter is covered in the main article Energy metering in the distribution board.
For the batteries from Anker, Marstek, EcoFlow and Zendure checked here, yes: all of them name the Shelly Pro 3EM, Anker and Zendure also the older Shelly 3EM. What counts is the list for your own battery model, because it differs from device to device. The Solarbank 3 E2700 Pro, for example, accepts only these two Shelly models besides the Anker Smart Meter.
For any meter that goes on the DIN rail in the distribution board and puts current transformers around the line conductors, yes. Anker recommends a qualified electrical contractor for the Smart Meter Gen 2, Marstek requires an electrician for the CT002, and EcoFlow and Zendure do the same for the Shelly. A reading head on the digital electricity meter needs no work on the installation; Marstek explicitly says the CT003 can be installed without an electrician.
Usually the meter is not yet outputting the instantaneous power. On a German modern metering device, the INFO interface only provides it in the extended data set, which you unlock on the meter after entering the PIN. The PIN is issued by the metering point operator: at Netze ODR online with the meter number and market location number, at Netze BW through customer service.
The Shelly through the built-in Shelly integration, without the cloud. The Anker SOLIX Smart Meter Gen 2 through Anker's official integration over Modbus TCP, once Modbus TCP is switched on in the Anker app. The everHome EcoTracker through its local REST interface. For the first Anker Smart Meter there is only a community integration via the Anker cloud. With Marstek, the battery passes on its meter's readings via its local Open API; for Zendure's meters the manufacturer describes no route.
The information comes from the manufacturers' support pages, manuals and product pages, from the Home Assistant documentation and from the user manual of a metering operator. I do not run any of these batteries myself; this page is a sourced overview, not a field report. The compatibility lists change with the firmware. What is written here applies as of 13 October 2026.
Haag Automation has no business relationship with any of the manufacturers named. This article replaces neither the manufacturer's documentation nor your grid operator's technical connection conditions. Work in the distribution board and the meter cabinet is reserved for a qualified electrician.
Links marked with an asterisk are affiliate links. As an Amazon Associate I earn from qualifying purchases; the price is unchanged for you. What I recommend does not depend on it.
Want the meter installed so that the battery and Home Assistant see the same readings? I can set it up with you – the first conversation is free.