Technical article · Photovoltaics · EEG

Germany's solar peak law

Since 25 February 2025, three rules apply to new PV systems in Germany that did not exist before: they may export only 60 percent of their capacity until a smart meter is installed. They receive no tariff when the exchange price is negative. And in return their tariff period is extended. Existing systems are left out – but can switch voluntarily. This page explains all three rules with the wording of the EEG.

Official name
Gesetz zur Änderung des Energiewirtschaftsrechts zur Vermeidung von temporären Erzeugungsüberschüssen
Published
BGBl. 2025 I No. 51 of 24.02.2025
Applies to
commissioning from 25.02.2025
Export limit
60 % until smart meter (below 25 kW)
Negative prices
0 ct in those quarter-hours, compensation at the end
Status date
30 September 2026 · primary sources below, with the date each was checked
Author
Julian Haag, state-certified electrical engineering technician

Who it applies to

“Solarspitzengesetz” (solar peak law) is a nickname. Officially it is the Act amending energy industry law to avoid temporary generation surpluses, promulgated in the Federal Law Gazette on 24 February 2025. It is not a statute of its own but mainly amends the EEG – and that is also where it says which rules apply to which systems.

The dividing line is 25 February 2025. The EEG states it in its transitional provisions from the other side: for systems “commissioned after 31 December 2022 and before 25 February 2025”, the negative-price rules apply as they stood on 24 February 2025 (§ 100(46)), and the new 60 percent limit “shall not apply” (§ 100(3b)).

In short: if you built before 25 February 2025, nothing changes – unless you choose it yourself. If you have built since then or are building now, all three rules apply.

Rule 1: 60 percent export

§ 9(2) sentence 1 no. 3 EEG requires operators of systems receiving the feed-in tariff “with an installed capacity of less than 25 kilowatts” to “limit the maximum active power export to 60 percent of installed capacity” at the grid connection point. This applies “until smart metering systems and control units have been installed” and until the grid operator has successfully tested that the system can be controlled.

Three points make the rule less drastic than it sounds:

From 25 kW the same limit applies to systems receiving the feed-in tariff, there in addition to the duty to make export remotely reducible (no. 2).

Rule 2: no tariff at negative prices

§ 51(1) EEG is a single sentence: “For periods in which the spot market price is negative, the reference value is reduced to zero.” Since the solar peak law, these periods are quarter-hours. Anything exported during a quarter-hour with a negative price earns nothing.

Small systems get a postponement. Under paragraph 2 the rule does not apply to “installations with an installed capacity of less than 100 kilowatts for periods before the end of the calendar year in which the installation is equipped with a smart metering system”. In other words: a rooftop system without a smart meter is still paid in full. If the smart meter arrives in May, the zero rule applies from 1 January of the following year.

Rule 3: compensation at the end

What is lost in those quarter-hours is not cancelled but appended. § 51a extends the tariff period by the quarter-hours in which the tariff was zero. For solar systems, however, not one to one:

Full-load quarter-hours per month (§ 51a(2) EEG)
JanFebMarAprMayJun
87189340442490508
JulAugSepOctNovDec
49845337123111873

Whether the compensation really covers the loss can only be said for an individual system in 20 years – it depends on how often negative prices occur until then. The transmission system operators publish the number of affected quarter-hours every year by 31 January.

Existing systems: voluntary switch

Owners of older systems can still opt into the new rules. § 100(47) EEG allows systems whose tariff has not so far been reduced at negative prices to switch – “if the operator declares in text form to the grid operator that these are to apply”. The conditions:

The switch pays off the less the system actually exports at midday. Anyone who directs the midday surplus into a battery, an electric car or an immersion heater loses little in the negative quarter-hours – and gets the 0.6 cents on everything else. Anyone exporting at full power at midday should do the numbers first.

What it means for batteries and control

Both rules target the same hours: the sunny midday when there is too much solar power in the grid. A system that absorbs its own surplus at exactly that time is hardly affected by either. That is why the solar peak law is, at its core, an argument for control:

The law also set out when power from a battery that is also charged from the grid can still be paid under the EEG. § 19 EEG provides three routes: the exclusivity option for batteries charged only with green power, the delimitation option with a measured share, and the flat-rate option for systems up to 30 kW, under which at most 500 kWh per kilowatt and year is supported. The details of proof and metering are set by a determination of the Federal Network Agency under § 85d EEG.

And looking ahead: the EEG 2027 bill continues the line – the tariff at negative prices stays at zero, and for new small systems the fixed feed-in tariff disappears altogether.

Frequently asked questions

Does the solar peak law apply to my existing PV system?

No, not automatically. The new rules apply to systems commissioned since 25 February 2025. Systems commissioned between 1 January 2023 and 24 February 2025 expressly keep the previous version of the negative-price rules and are exempt from the 60 percent limit. Existing systems can switch voluntarily, however.

What does the 60 percent limit mean?

New systems below 25 kW receiving the feed-in tariff may export at most 60 percent of their installed capacity at the grid connection point – until a smart meter with a control unit has been installed and successfully tested. The limit applies to export to the grid, not to generation: power used in the house or charged into a battery does not count. Balcony solar units are exempt.

Do I no longer get a feed-in tariff at negative prices?

New systems of 100 kW or more lose it immediately; smaller systems only after the calendar year in which a smart meter was installed. From then on, the tariff falls to zero in every quarter-hour with a negative exchange price. In return, the tariff period is extended beyond the 20 years.

Is the voluntary switch worthwhile for existing systems?

That depends on how much the system exports during hours with negative prices. Those who switch receive 0.6 cents more per kilowatt-hour but lose the tariff in those quarter-hours. The switch is only possible with a smart meter, at the earliest at the end of the year it was installed, and is declared in text form to the grid operator. Anyone who exports little at midday thanks to a battery or large loads loses little.

What does a battery have to do with the solar peak law?

It is the obvious answer to both rules: it absorbs the midday surplus that would otherwise be curtailed at the 60 percent limit or exported without payment during quarter-hours with negative prices. The law also newly regulates when power from a battery that is also charged from the grid can still be paid under the EEG.

Sources

All information comes from the following documents, each with the date it was checked. The EEG is quoted in its currently applicable version. All sources are in German.

This article is not legal advice. Which version applies to a system depends on its commissioning date; if in doubt, the grid operator can tell you.

Want to control your battery, wallbox or immersion heater so that the midday surplus stays in the house? Write to me – the initial consultation is free.