Charging your EV from solar surplus

Your wallbox charges with the power your array happens to have spare – not with power you buy back from the grid at a much higher price. I bring your existing wallbox into the energy management system, entirely local in Home Assistant, with no vendor cloud involved. On site around Heilbronn, Ludwigsburg and the Stuttgart region, remotely across Germany and Austria.

Service
Wallbox integration – price on request
Included
Integration, surplus control, charging profiles, dashboard, functional test, handover
Prerequisite
A wallbox with an open interface, metering at the grid connection point
Area served
Ilsfeld, Heilbronn, Ludwigsburg, Stuttgart region · remote across Germany and Austria
Last reviewed
September 2026 · every legal and standards figure sourced below

What surplus charging actually means

A solar array produces very unevenly across the day. Whatever the house is not consuming at that moment goes out to the grid, at a feed-in rate well below what you pay for the power you draw back. That gap is the entire point: every kilowatt-hour that ends up in the car battery instead is money kept.

So surplus charging means the wallbox is continuously told how much current it may draw right now, so that the draw from the grid stays at zero. A cloud rolls in, the charging power drops. The sun comes back, it rises again. This is not an on/off switch but an ongoing control loop.

The six amps where it breaks down

This is the point almost every sales conversation skips – and it decides whether surplus charging works for you on thirty days a year or on two hundred.

A wallbox cannot be throttled arbitrarily far down. The IEC 61851 charging standard specifies 6 amps per phase as the minimum current. Below that, charging stops. That minimum current sets a hard floor for charging power, and the floor depends on how many phases are used:

Single-phase
1.4 kW to 3.7 kW
Two-phase
2.8 kW to 7.4 kW
Three-phase
4.1 kW to 11 kW or 22 kW

The mistake made at purchase: the usual three-phase 11 kW wallbox needs around 4.1 kW of surplus before it even starts. A 10 kWp array never reaches that on an overcast November day, and even in summer only once the household and the heat pump have been served. The wallbox then sits idle while 2 kW run unused into the grid.

The answer is automatic phase switching (1p/3p). A wallbox that supports it charges single-phase from 1.4 kW when surplus is thin, and steps up to three phases once more than 4.1 kW is available. That is what makes the marginal hours usable – mornings, late afternoon light, overcast days. It is the difference between a feature on the datasheet and one that earns its keep in daily use.

So that the switching does not keep interrupting the session, the control works with delays: the surplus has to be present continuously for a while before charging starts, and a brief dip does not stop it immediately. Those two intervals are the real fine-tuning – too short and the wallbox clicks at every passing cloud; too long and surplus is wasted.

What your wallbox has to be able to do

Not every wallbox is suitable. Before I set anything up, I check four things:

If the existing wallbox turns out to be unsuitable, I say so before you place the order – not after I have spent a day trying to force it anyway.

Where the surplus figure comes from

You can only control what you measure. The decisive figure is not what the array generates but the power at the grid connection point: how much is flowing out right now, how much is being drawn in? Only that value accounts for what the household, the heat pump and the battery are doing at the same time.

Where it comes from depends on the house. Often the solar inverter supplies it over Modbus, sometimes it takes a separate meter that I add in the meter cabinet. Where that is necessary, it belongs to energy monitoring rather than to wallbox integration – and we say so beforehand instead of billing it afterwards as an add-on.

Charging by price instead of by sunshine

Not every charging session fits into the midday hours. If you come home in the evening and need a full battery by morning, you can charge by exchange price instead: Home Assistant pulls the hourly prices, finds the cheapest window before your departure time and puts the session there.

This requires a dynamic electricity tariff. Under Section 41a EnWG, every electricity supplier has had to offer one since 1 January 2025 – previously the obligation applied only to suppliers with more than 100,000 end customers. The condition is that the customer has a smart metering system as defined by the German metering point operation act.

The two approaches are not mutually exclusive, incidentally. The common combination: charge on surplus during the day, and if that does not suffice before departure, top up during the cheapest grid hours.

Registration and Section 14a EnWG

Two legal points apply to every wallbox, regardless of how it is controlled.

Registration. Under Section 19 paragraph 2 of the German low-voltage connection ordinance (NAV), charging equipment for electric vehicles must be reported to the grid operator before it is put into service. If the total rated power exceeds 12 kilovolt-amperes per electrical installation, the operator's consent is required on top of that. The operator has to respond within two months of receipt; if it refuses, it must set out the obstacle, possible remedies and the time required.

Widely repeated, but wrong: a lower threshold of 3.6 kVA below which nothing needs reporting. Section 19 NAV says no such thing – it names charging equipment without a power threshold. The 12 kVA figure is the boundary for consent, not for the duty to report.

Controllability. A private charging point drawing more than 4.2 kW of grid connection power is a controllable consumption device under Section 14a EnWG. The grid operator may temporarily limit its draw during congestion, and in return you receive a reduced grid fee. What that means for planning, the meter cabinet and the choice of module, I have written up in detail: Section 14a EnWG in practice.

What the work involves

Frequently asked questions

How much solar surplus do I need before the wallbox charges at all?

That depends on the number of phases. The IEC 61851 charging standard specifies a minimum current of 6 amps per phase. Three-phase, that comes to roughly 4.1 kW; single-phase, roughly 1.4 kW. So a three-phase wallbox without switching stays idle as long as the surplus is below 4.1 kW.

Do I need a wallbox with automatic phase switching?

For surplus charging worth having, yes. It lowers the entry threshold from roughly 4.1 kW to roughly 1.4 kW, which is what makes the hours usable when the array is not at full output – mornings, evenings, overcast days. Without switching, surplus charging is limited to a few hours in summer.

Do I have to register my wallbox with the grid operator?

Yes. Under Section 19 paragraph 2 of the German low-voltage connection ordinance (NAV), charging equipment for electric vehicles must be reported to the grid operator before it is put into service. If the total rated power exceeds 12 kilovolt-amperes per electrical installation, the operator's consent is required as well.

Does this work without the wallbox manufacturer's cloud?

In most cases yes. Wallboxes offering Modbus/TCP, MQTT or OCPP can be addressed entirely on the local network. The control then keeps running even if the internet connection drops or the manufacturer discontinues its service.

Can I have my wallbox charge according to the electricity price?

Yes, if you have a dynamic electricity tariff. Under Section 41a EnWG, every electricity supplier has had to offer one since 1 January 2025, provided the customer has a smart metering system installed. Home Assistant pulls the hourly exchange prices and places charging in the cheap hours.

Sources

What binds you are the technical connection conditions and the registration procedure of your responsible distribution grid operator. This page replaces neither their guidance nor legal advice.

Do you have a wallbox and a solar array that know nothing about each other? Message me on WhatsApp or get in touch another way – the initial consultation is free.