Technical article · Interfaces

Dynamic tariffs by interface quality

This article compares no prices. It compares what a controller actually depends on: when the data arrives, how fine it is, what it contains at all – and how you notice when it has not arrived.

Perspective
Data quality rather than markup and standing charge
Key criterion
Exchange price or the price actually billed
Most common mistake
checking that data exists instead of how old it is
Belongs to
the hub „Home Assistant as an energy manager“
Status
September 2026 · primary sources below, with the date checked
Author
Julian Haag, state-certified electrical engineering technician

Why this is not a price comparison

Comparisons of dynamic tariffs are plentiful, and nearly all compare the same things: the markup on the exchange price and the standing charge. Fair enough, but it does not answer the question that arises the moment a controller depends on the tariff: is the interface good enough for an automation that has to run every day?

The markup decides a few euros a month. The interface decides whether the heat pump makes the right call tomorrow morning. Anyone building control therefore sensibly picks on data quality first and price second – not the other way round.

The criteria

What the documentation gives you

Two interfaces are common in the German-speaking market and publicly documented.

Through the supplier. Here the interface hangs on the contract: queries carry a personal token and return prices for your own connection – including the components actually billed. Next-day prices are, according to the documentation, available in the window between 12:00 and midnight.

Through raw market data. No contract needed: the interface returns exchange prices as JSON at hourly resolution, queried with a start and end time. The data comes from the power exchange and, according to the provider, is updated daily at 14:00 for the following day; use is free under a fair-use principle of 100 queries per day.

The decisive difference is not technical but editorial: market data is the exchange price; the supplier interface returns the price that ends up on the bill. Control optimising on exchange prices shifts load along a curve that reflects only part of what a kilowatt-hour costs – and is especially wrong once time-variable grid fees enter the picture.

What happens when nothing arrives

Neither interface is failure-proof, and neither needs to be. What matters is whether the failure is detectable. Three cases exist:

Practical consequence: do not check whether data exists but how old it is. If the newest values are older than the expected interval, treat the data as invalid. What such a fallback looks like is covered in the article on price-signal automation.

What follows for the build

The criteria lead to an unspectacular recommendation: do not hard-wire the price source into the control logic. Keeping the price list as an entity of its own, with the automation reading only from it, lets you swap the source without touching the rules – and, in an emergency, enter a curve by hand.

The second consequence: what counts is the price that gets billed. If the available source carries only the exchange price, the remaining components belong in the calculation – otherwise the system optimises cleanly against the wrong curve.

The hub on this topic: what the price source sits on top of – hardware, installation type, metering and storage – is covered in Home Assistant as an energy manager.

Sources

All statements come from the providers' public documentation, with the date retrieved. Interfaces and terms of use change – check the current state before building control on one.

This article is not a tariff recommendation and compares no prices. What governs your bill is your contract; what governs the interface is its current documentation.

Want control that survives a change of provider – and does not decide wrongly when the data stops? Write to me – the first conversation is free.