Section 14a EnWG in practice
What Section 14a EnWG means for heat pumps, wallboxes and batteries: grid-oriented control, 4.2 kW, reduced grid fees – with the regulator's sources.
Articles
All 83 articles on this site, grouped by topic, each with its short description. The services I offer are on the home page.
What Section 14a EnWG means for heat pumps, wallboxes and batteries: grid-oriented control, 4.2 kW, reduced grid fees – with the regulator's sources.
The 4.2 kW are neither a registration threshold nor a state-level rule. What the figure means, why it appears twice – with the wording of the ruling.
Making a heat pump, wallbox or battery controllable: the three routes for the control signal, the EEBUS minimum standard, five questions for the maker.
Not a shutdown but a limit: where operators must disclose their interventions, what reaches the installation, and what to log yourself.
Heat pump or wallbox in operation before 2024? Which of three transition rules applies, what happens on 1.1.2029 and when switching early pays off.
No APZ panel, no space? Three ways to fit the section 14a control box into an existing meter cabinet, which cables and which power supply – per Netze BW.
Control box due after the KfW deadline? Which BEG version applies to your application, what it requires on controllability, and why you need not wait.
Flat rate, 40 % energy price or time windows: the three grid fee modules under section 14a EnWG, calculated with Netze BW's 2026 price sheet.
Which section 14a grid fee module saves you more? Calculator with your grid operator's prices: flat rate, 40 % energy price and time windows.
When a German wallbox must be controllable under section 14a, what “compliant” means technically and how to retrofit: control input, EMS or contactor.
What grid operators handle differently under section 14a EnWG, compared – plus every German electricity grid operator with website, e-mail and phone.
What Netze BW requires under section 14a EnWG: registration, meter position with RJ-45 and EEBus, 2026 grid fees, existing systems, operator duties.
What NHF and NHL in Heilbronn, Lauffen, Flein, Talheim and nearby require under section 14a: coupling relay, control times, minimum power, grid fees 2026.
Netze ODR and section 14a EnWG: terminal strip and RJ-45 always, two routes in old cabinets, grid fees 2026 with module 3 only from April to September.
Syna and section 14a EnWG: no separate TMA, isolating relays, adapter plate in old cabinets, grid fees 2026 with module 3 in winter only.
How Daikin, Bosch, Buderus, Vaillant, Viessmann, Weishaupt, go-e, Easee, KEBA, Fronius, SMA, GoodWe and Sigenergy handle section 14a, each with its source.
How KEBA KeContact P40 and P30 meet section 14a: switch contact X1 with adjustable charging current, Modbus TCP or OCPP – per the installation manual.
How Heidelberg and Amperfied wallboxes meet section 14a: Modbus via an EMS or a potential-free contact – and what applies to older models.
How go-e Charger Gemini, Gemini flex, PRO and CORE meet section 14a: potential-free input, Modbus TCP or contactor – per go-e's conformity document.
How Easee wallboxes meet section 14a EnWG: control box contact to metering solution and Equalizer, control levels, radio or Wi-Fi – and why EEBUS is out.
How the Fronius Wattpilot meets section 14a: digital input on Home 2.0 and Flex, not on the Go – and why it must stay online in Germany.
How SMA implements section 14a: direct control of the chargers via digital inputs or control via the Sunny Home Manager 2.0 over EEBus – with setup.
How Sigenergy systems implement section 14a: control box contact on DI5 of the Energy Controller, EnWG14a option in the app – and two points to clarify.
How GoodWe ET series hybrid inverters implement section 14a: the DRM/RCR/EnWG port, the SolarGo app setting – and what section 14a means for the battery.
How a Stiebel Eltron heat pump meets section 14a EnWG: utility contact or power limitation via ISG Connect, by relay, Modbus or KNX – and what is missing.
How Vaillant heat pumps meet section 14a EnWG: utility contact, EEBUS via the internet module or energy management – with prerequisites and a subsidy note.
How a Viessmann Vitocal 250-A implements section 14a EnWG: power limitation via contact 143.4, consumption limit setpoint, heater included.
Bosch and Buderus connect heat pumps to the control box via EEBus or the SG1 contact: which units, from which software, what the subsidy requires.
How a Weishaupt heat pump meets section 14a EnWG: power limitation via the controller input or SG Ready 1.1, factory-set to 4.2 kW – and why no contactor.
How a Daikin Altherma meets section 14a EnWG: utility contact, EKRP1AHTA board or HomeHub with EEBUS – what curtailment does and what subsidies require.
German feed-in tariff 2026: 7.70 ct for 20 years if commissioned by 31 Dec. From 2027 the EEG bill offers only 5.2 ct for 3 years. The facts, with sources.
60 percent export limit, no tariff at negative prices, compensation at the end: what Germany's Solarspitzengesetz has regulated since February 2025.
PV system, battery, balcony solar: who must register in Germany's market master data register, by when – and why forgetting costs €10 per kW and month.
Which diagram is accepted when registering a PV system: the requirement from VDE-AR-N 4105, what Netze BW asks for, and five sample sheets as PDF.
What Stromnetz Berlin requires in the single-line diagram of a PV system: modules, cables, meter panel, existing and new parts – with five sample sheets.
What EWE Netz requires in the single-line diagram of a PV system: metering, module and inverter assignment per building, uploads – with five sample sheets.
Which hardware, which installation type, how much storage – and the four things an energy manager does not need at all.
Direct or transformer measurement, how much room the board needs, and why reconciling against the utility meter is the step that matters.
Add the Shelly Pro 3EM, assign import, export and power correctly – and why the Shelly counts differently from the utility meter once PV feeds in.
Seven Shelly energy meters compared: measuring range, CTs, mounting, network. Which one fits which connection and what the Pro 3EM v2 changes.
Which meters do Anker, Marstek, EcoFlow and Zendure accept, which needs an electrician and which delivers its readings locally to Home Assistant?
Raw values gone after 10 days, hourly statistics kept forever: how Home Assistant stores long-term data, why state_class matters, when InfluxDB pays off.
What the Home Assistant MCP server exposes to a language model, what is exposed by default, and why it does not replace automations.
Since the ElWG, Austrian smart meters store 15-minute values. Who may still object under section 54(2), and how Home Assistant reads the meter locally.
Animara icons for PV, battery, wallbox and heat pump in Home Assistant: installation, a test with a simulated system, and what did not go smoothly.
How to calculate solar self-sufficiency and self-consumption correctly, how battery losses and sensor errors inflate the figure, and what the meter shows.
Connect Claude to Home Assistant: as a voice assistant via the API, through the MCP server in the Claude app, or in Claude Code. Costs, rights, setup.
Victron GX locally in Home Assistant: enable MQTT on the Cerbo, get battery and PV into the energy dashboard, and what the VRM integration delivers.
Fronius inverters locally in Home Assistant: enable the Solar API on the Gen24, get the battery into the energy dashboard, set limits via Modbus TCP.
SMA inverters locally in Home Assistant: what the core integration does, why ennexOS and the Home Manager are excluded, and which routes work there.
HM, HMS, HMT or HMS-…W: which radio module belongs to which Hoymiles, which ESP32 fits, when OpenDTU does not work and how readings reach Home Assistant.
Zero export for balcony solar and batteries in Home Assistant: when Germany requires it, how metering and control work and why it never quite hits zero.
Forecast.Solar, Solcast or Open-Meteo: what a PV forecast in Home Assistant costs, how to set it up and why the azimuth is so often wrong.
Venus E 3.0, A, D, E 2.0, B2500, Jupiter: which Marstek reaches Home Assistant locally via Open API, Modbus or MQTT, and which integration fits.
Self-consumption or arbitrage? Why that question precedes the device choice, what controllability really means, and why two controllers cannot run at once.
Spread minus efficiency loss minus cycle cost: the complete calculation, distribution instead of average – and when the result is negative.
ESS already regulates itself. How to set the setpoint from outside, which route is suitable, and what goes wrong when releasing it.
How many PV panels do you have? The configurator proposes charge controllers, MultiPlus and battery – with parts list, BMS cable, meter and settings.
Immersion heater, power controller or heat pump: why the calculation usually goes against the heater – and the four cases where it does not.
Relay, Modbus or cloud? What German funding has required since July 2026, how a price signal drives a heat pump, and where the limits are.
Ranking instead of thresholds, when the price data actually arrives, and what happens when it does not – an automation that survives an outage.
Not by markup but by API: publication time, resolution, completeness, and what happens when no data arrives at all.
When an optimiser beats an automation, which data it needs, and why the objective function decides what you get.
ViCare integration with client ID and rate limit, local Optolink, or CAN bus on E3 devices: which route brings a Viessmann boiler into Home Assistant.
How the optical service interface works, how to attribute data points reliably, and which of them an energy manager actually needs.
Net metering in the Netherlands ends on 1 January 2027. How Home Assistant measures the cost at the P1 port and keeps solar surplus at home.
Solar Sharer in NSW, SE QLD and SA: three free hours, 24 kWh cap. How Home Assistant moves battery, EV and hot water into the window.
Install evcc as a Home Assistant app, use meters from Home Assistant, add the ha-evcc integration – and when you need a sponsor token.
Which wallbox evcc controls with phase switching and which needs no sponsor token: 40 models from evcc's templates, fixed and mobile, plus notification.
Surplus and price charging contradict each other. Setting the price limit, deciding who gets the electricity first, and what can really be shifted.
Eight articles on the Ilsfeld heat network: wastewater heat, the price formula, heat planning, leak detection, cold networks – all from primary sources.
How a German heat network turns 10 °C wastewater into an 80 °C flow: the cascade of heat pump and CHP unit, with temperatures, capacities and sources.
Cold network or hot network? Temperatures, insulation, losses and who runs the heat pump – explained at a network that operates both in parallel.
Weld twelve metres or unroll five hundred: how pipe material decides build time, trench width and cost in a heat network – and where steel stays.
A heat network loses 650 litres a day and four detection methods find nothing. What that does, how you search, and where measurement reaches its limits.
How a district heating price formula works: seven weighted components, official price indices, and one real tariff worked through in full.
A suitable area is not a right of connection: what a municipal heat plan legally means and what the new German building law changes for boiler replacement.
Germany’s heat network funding (BEW): the four modules, why operating cost support matters – and how a biomass cap ruled out a wood-fired boiler.
Heilbronn's heat plan: 13 suitable areas, target year 2035. Plus the duty under state and federal law, deadlines and the status in the Heilbronn district.
20.5 MW of solar on 1,342 systems: installations since 1995, two build-out waves, batteries and municipal roofs – from the German energy register.
Case study: a Viessmann Vitoladens 300-W read through a self-built Optolink head in Home Assistant – reading and writing, entirely local.
Case study: a tipping-bucket rain gauge with ESPHome in Home Assistant – calibrated against real millimetres, not against counted tips.
Own design: a 19" 1U mount for one or two ThinkCentre Tiny. Rubber feet stay on, only four screws. PETG, in daily use. STL freely available.