Austria · Smart meter
Section 54 ElWG: smart meters and 15-minute data
Who in Austria may still object since the ElWG – not with a PV system –, what is transmitted anyway and how Home Assistant reads the customer interface.
Read the article →Articles from Ilsfeld · Heilbronn region
Energy topics for your own home – based on primary sources and dated.
This is where I write up what I have checked on § 14a EnWG, heat networks and municipal heat planning, solar PV and Home Assistant: rules, funding and engineering, backed by the source they come from. Alongside, projects of my own, documented so they can be rebuilt.
Technical articles
Articles on energy topics that get concrete in this region: the rules for controllable heat pumps and wallboxes, the engineering behind the Ilsfeld heat network, the local solar stock and control with Home Assistant. All worked through from primary sources, dated, and without marketing figures. The articles on local heat and power supply are collected on an overview page about heat supply in Ilsfeld.
Austria · Smart meter
Who in Austria may still object since the ElWG – not with a PV system –, what is transmitted anyway and how Home Assistant reads the customer interface.
Read the article →Home Assistant · AI
What a language model may switch via MCP, which devices are exposed out of the box – garage door included – and why it does not replace an automation.
Read the article →Section 14a · Grid operator
Terminal strip and RJ-45 always, two routes in existing meter cabinets and a module 3 that applies only from April to September in 2026 – with a night-time high tariff.
Read the article →Section 14a · Grid operator · Heilbronn
Radio ripple control receiver, 230 V coupling relay, control times per feeder and grid fees 2026 – for Heilbronn, Lauffen, Flein, Talheim and nearby.
Read the article →Heat · Heilbronn region
A duty for every municipality since 2025, deadlines until 2028, Heilbronn's heat plan with 13 suitable areas and the status in the district's 46 municipalities.
Read the article →Home Assistant · Photovoltaics
Switch on the Solar API on the Gen24, get the battery into the energy dashboard with a Riemann sum and, since 2026.9, set limits via Modbus TCP.
Read the article →Home Assistant · Photovoltaics
The core integration reads locally, but only Webconnect. What helps with the Tripower X, the Energy Meter and the Sunny Home Manager 2.0.
Read the article →Home Assistant · Heating
Cloud with a client ID and 1450 calls a day, local Optolink on the Vitotronic, or CAN bus on E3 devices – which route fits which device.
Read the article →Home Assistant · E-mobility
Install it as an app, use meters from Home Assistant, add ha-evcc – and which wallboxes need a sponsor token, go-e included.
Read the article →Wallbox · evcc
Phase switching, sponsor token, fixed or mobile: 40 wallboxes from the evcc templates, plus the duty to notify the grid operator.
Read the article →Home Assistant · Photovoltaics
When it is required and when merely useful, how metering and control work – and why it never quite hits zero on load changes.
Read the article →Home Assistant · Photovoltaics
NRF24L01+ or CMT2300A, which ESP32, and why the models with a W in the name do not run with OpenDTU.
Read the article →Metering · Battery
Which meter Anker, Marstek, EcoFlow and Zendure accept, who installs it and which one delivers its readings locally to Home Assistant.
Read the article →Home Assistant · Battery
Open API, Modbus or MQTT: which Marstek battery can be integrated locally, with Marstek's own and community integrations.
Read the article →Home Assistant · Photovoltaics
Forecast.Solar, Solcast or Open-Meteo: account, planes, request limits – and four conventions for the azimuth of the same roof.
Read the article →Home Assistant · Energy
Adding it, assigning import and export correctly – and why the Shelly counts differently from the utility meter once PV feeds in.
Read the article →Metering · Shelly
Seven Shelly energy meters by data sheet: which measuring range fits which connection and what the Pro 3EM v2 changes.
Read the article →Section 14a · Wallbox
When the wallbox must be controllable, how much charging remains during curtailment and how to retrofit: control input, energy management or contactor.
Read the article →Home Assistant · Data
Raw values gone after 10 days, hourly values kept forever – why the state class decides and when InfluxDB pays off.
Read the article →Photovoltaics · EEG 2027
5.2 cents for three years instead of 7.70 cents for twenty: what the bill says, what applies until 31 December and when building quickly pays off.
Read the article →Photovoltaics · Export
60 percent export limit, no tariff at negative prices, compensation at the end – and the voluntary switch for existing systems.
Read the article →Photovoltaics · Registration
One month's deadline, €10 per kW and month if it passes – and registration step by step.
Read the article →Section 14a · Manufacturers
Daikin, Bosch, Buderus, Vaillant, Weishaupt, go-e, Easee, KEBA, Fronius, SMA, GoodWe, Sigenergy: which route, which interface, which document date.
Read the article →Section 14a · Grid operators
Interface, old meter cabinets, flat rate and module 3 compared – plus every German electricity grid operator with website, e-mail and phone.
Read the article →Grid connection · Choosing devices
The three routes for the control signal, the EEBUS minimum standard and five questions to settle before buying.
Read the article →Section 14a · Grid fees
Flat rate, reduced energy price or time windows – calculated with the 2026 price sheet, including the break-even at around 2,730 kWh.
Read the article →Section 14a · Calculator
Work out module 1, 2 or 1 + 3 with your consumption and your grid operator's prices – including break-even and full calculation.
Open the calculator →Section 14a · Existing systems
Heat pump from before 2024: which of three transition rules applies, what happens on 1.1.2029 and when switching pays off.
Read the article →Section 14a · Grid operators
Registration, meter position, control, grid fees 2026 and the duties after commissioning – from Netze BW's own documents.
Read the article →Section 14a · Meter cabinet
No APZ panel, no space: three ways per Netze BW, plus interface, cables and power supply.
Read the article →Grid connection · Heat pump
Not a registration threshold, not a state-level rule – and the figure appears twice in the ruling, meaning different things.
Read the article →Photovoltaics · Grid connection
Which diagram the grid operator requires, what has to be on it – and five finished sample sheets as PDF.
Read the article →Metering · Distribution board
Direct or transformer measurement, the space it really needs, and the reconciliation against the utility meter that almost everyone skips.
Read the article →Automation · Dynamic tariff
Ranking instead of thresholds, when the data arrives, and what the automation does when it does not.
Read the article →Grid connection · Measurements
A limit rather than a shutdown – what arrives in the house, and what the three grid fee modules are worth.
Read the article →Self-consumption · Hot water
Immersion heater, power controller or heat pump – why the calculation usually goes against the heater.
Read the article →Basics · Energy management
Hardware classes, installation type, storage and backup – and the four things it does not need.
Read the article →Interfaces · Tariffs
Not a price comparison: publication time, resolution, completeness and behaviour on failure.
Read the article →Electric mobility · Dynamic tariff
Surplus and price charging contradict each other – and how the priority between car, heat and battery is settled.
Read the article →Heating data · Local
Optolink instead of cloud – attributing data points reliably and picking the few control actually needs.
Read the article →Storage · Dynamic tariff
Self-consumption or arbitrage, local access as a purchase criterion – and why two controllers cannot run at once.
Read the article →Economics · Storage
Spread minus efficiency loss minus cycle cost – and why the average is the wrong number.
Read the article →Optimisation · Home Assistant
When an optimiser beats a rule – and why the objective function decides what you get.
Read the article →Configurator · Victron
Parts list for a MultiPlus-II with Pylontech, BYD, Dyness and others: which BMS cable, which meter, which settings.
Open the configurator →Storage · Victron
Set the setpoint rather than replace the controller – and what happens when releasing it is forgotten.
Read the article →Heat pump · Dynamic tariff
Relay, Modbus or the manufacturer's cloud: the three routes compared, the digital interface required since July 2026, and the pitfalls of the automation itself.
Read the article →Regulation · Energy management
Who falls under the rules, why 4.2 kW means two different things, and when an energy management system is the better answer.
Read the article →District heating · Heat pump
The cascade of heat pump and CHP unit that turns 10 °C wastewater into an 80 °C flow – and why heat density decides the losses.
Read the article →Solar · Data
1,342 systems totalling 20.5 megawatts from the German energy register: two build-out waves, 556 batteries, three operating models on public roofs.
Read the article →District heating · Pricing
Seven weighted components, worked through in full from a real tariff sheet – and why price movements always reach the customer late.
Read the article →Planning · Regulation
A suitable area is not a right of connection. What the plan legally means and what the new Building Modernisation Act requires when replacing a boiler.
Read the article →Network design · Technology
Two networks built on opposite logic: where the heat pump sits, why cold networks need no insulation, and which fits where.
Read the article →Maintenance · Measurement
Four detection methods, each with its own blind spot – and the case where no water escapes at all but merely changes circuit.
Read the article →Network construction · Material
How pipe material decides trench profile, build time and trades – and what it means for finding a leak later.
Read the article →Funding · Policy
The four modules of Germany's heat network funding – and how a cap on biomass ruled out a planned wood-fired boiler.
Read the article →My own projects
What I write about, I test on my own system first. Three projects are fully documented – including every source used for 3D models and code, so you can follow and rebuild them.
Heating · Energy monitoring
A Viessmann Vitoladens 300-W brought into the smart home through a self-built optical read head – read and write, with oil consumption in the energy dashboard and fault monitoring that still works when the data link dies. Fully local, no manufacturer account.
View project →Sensors · Custom build
A 3D-printed tipping-bucket rain gauge, connected to Home Assistant via an ESP8266 – with a calibration that turns counted tips into genuinely reliable millimetres of rainfall. The basis for irrigation and cistern control.
View project →Design · 3D printing
A self-designed mount that puts one or two mini PCs into a 19" rack in a single rack unit – without taking the machine apart, using four screws. Printed in PETG and proven in continuous operation. The STL files are freely available.
View project →Services
The articles are meant to be complete enough that you do not need to hire anyone. If you would still rather hand it over, there are two things I offer.
Photovoltaics · Registration
€50per diagram
Drawn from your details: single-line from the grid connection, with metering concept and equipment identifiers, as a PDF for your electrician.
Service details →Home Assistant · Heilbronn region
Price on request
Installation, device integration and energy management – local, without cloud lock-in. On site in the Heilbronn and Ludwigsburg region, remotely across Germany and Austria. This includes charging your EV from solar surplus.
Service details →Contact
Something missing from an article, a figure out of date, or a question about it? Write to me – every hint makes the articles better.
julian@haag-automation.comTelegram group (in German): t.me/haag_automation
About me: Julian Haag, electrical engineering technician
You'll usually receive a reply within one business day.
Haag Automation · Mühlstraße 35 · 74360 Ilsfeld